T8DCS Double Beam UV-Vis
T8DCS is a high performance double beam spectrophotometer with a continuously selectable spectral bandwidth from 0.1-5nm.
It meets various demands for spectral bandwidth from users in different industries especially pharmaceutical industry and scientic research field.
The Czerny-Turner Monochromator with a holographic grating keeps stray light to a minimum and offers excellent optical resolution.
The use of a photomultiplier tube as detector delivers exceptional sensitivity.
The T8DCS’ true double-beam optical system coupled with an efficient and well proven electronic control system ensures high stability and low background noise.
Key Features
◆ A high-performance double beam spectrophotometer with a variable spectral bandwidth from 0.1-5nm, selected by a continuous changeable slit
◆ User friendly design allows easy light source replacement and routine maintenance
◆ Large sample compartment design enables use of a wide range of accessories
T8DCS Double Beam UV-Vis Spectrometer - Brochure
<a
Specifications
Optical system | Double beam |
Scan speed | Selectable |
Wavelength range | 190-900 nm |
Wavelength accuracy | ±0.3 nm |
Wavelength reproducibility | ≤0.1 nm |
Spectral bandwidth | 0.1 – 5 nm Continually Adjustable |
Photometric mode | Transmittance, Absorbance, Energy Concentration, all using UVWin software |
Photometric range | -4.0-4.0 Abs |
Photometric accuracy | 0.002 A (0-0.5 A), 0.004 A (0.5-1 A), 0.3 %T (0-100 %T) |
Photometric reproducibility | 0.001 A (0-0.5 A) |
Photometric noise | 0.0004 A (500 nm, 30 min warm-up) |
Baseline flatness | 0.001 A (200-850 nm) |
Baseline stability | 0.0008 A/h (500 nm, 0 Abs, 2hrs warm-up) |
Stray light | ≤0.01 %T (220 nm NaI, 340 nm NaNO2) |
Standard functionality | No stand alone function |
Cell holder | Fixed position sample and reference |
Detector | Photo multiplier tube |
Light source | Tungsten Halogen and Deuterium arc lamps |
Display | No display |
Printer | Not available |
PC interface | RS232, USB |
Software support | UV Win |
Power supply | Switch mode 120-230 VAC 50-60 Hz |
Weight | 95 lb |
Dimension | 21.5 x 23 x 11 in |
Accessories & Spare Parts
-
UVWIN Software
Key Functions:
-Spectral Analysis
-Quantitative Analysis
-Kinetic Analysis
-DNA Protein Determination Analysis
-
PS19-3 Sipper Pump Accessory (Pump, Tubing, Cassette, Front Panel, Flow Cell, PS93+)
Description:
Pump speed: 0.1— 250 RPM
Speed resolution: 0.1RPM less than 30RPM Speed and 1 RPM above 30 RPM Speed
-
CH19-2 Constant Temperature Cell Holder (CH92+)
Description:
Wavelength range:190-900nm
Cell Path length: 10mm
Cell-holder Number: 2
Inner diameter of outside soft tube: Φ4mm
Requires PTC-2 Peltier
-
PTC-2 Peltier(W1050002)
Description:
Temperature range: 5-75℃
Use with constant temperature holder
-
SQ10/10 Cells Package (10x 10mm Quartz Cells,B207004)
Description:
10 x Quartz Cells
10mm path length
-
W-200 Tungsten Lamp(0111-10-010-06)
Description:
Wavelength range: 400-1100 nm
Life:>1000hrs
The bigger one in the picture is for T8DCS.
-
D2-200 Deuterium Lamp (DG0363024001)
Description:
Wavelength range: 190-400 nm
Life: >2000hrs
-
SS19-1 Short Path-length Cell Holder
Description:
Wavelength range: 190-1100nm
Path length: 1mm, 2mm, 5mm
-
TR19-1 Test Tube Holder 13-16mm Variable
Description:
Wavelength range: 190-900nm
Test tube diameter: 15~25mm
Test tube Height: 90~120mm
Cell holder number: 2
Used to put test tubes. It is easy for measurement of liquid contained in test tubes
-
IS19-2 Integrating Sphere (Diffuse Reflectance)
Description:
Incident angle: Sample 0°, reference 8° | Minimum dimensions: 15mm×25mm Diffuse reflectance |
Minimum dimensions: Diameter 20mm Transmittance | Wavelength range: 230-850nm 5nm slit | Sphere diameter: 58mm
-
MR19-1 Specula Reflectance Accessory
Description:
Incidence angle: 5°
Wavelength range: 200-900nm
Measured sample area: 30×15mm
-
MH19-2 Ultra Micro Cell Holder
Description:
Wavelength range:190-900nm
Cell holder number: 2
Micro cuvette or ultra-micro cuvette need to be used in the ultra-micro cell holder.
-
LS19-1 Universal 5-100mm Path Length Cell Holder (Sample & Reference)
Description:
Wavelength range: 190-900nm
Cell holder number: 2
Path length: 5mm,10mm,20mm,30mm,40mm,50mm,100mm
-
8 Position Cell Changer (Fixed Reference Position)
Description:
Wavelength range: 190-900nm
Cell holder number: 8
Path length: 10mm
-
ST19-1 Standard Sample Holder(SS19-2)
-
S19-1 Solid Sample Holder
Description:
Wavelength range: 190-900nm
Cell holder number: 2
Maximum sample size:80x55x5mm
-
DS19-1 Adjustable Angle Solid Sample Holder
Description:
Wavelength range: 190-900nm
Variable angle range: ±45°
Minimum sample size: φ4mm
Maximum sample size:80x55x5mm