L600 High Performance Liquid Chromatography
Contact for Quotation
The pump heads have been machined using a first-class CNC process; the
innovative structural design achieves minimum pressure fluctuation.
Consequently, stable flow, low noise and overall quality provide the foundation for reliable results.
LCWin software offers complete control, powerful data processing, reporting
functions, and intelligent diagnostic systems.
The included maintenance utility helps to ensure a complete and flexible software solution for your analytical work.
The L600 is a high performance yet cost-effective solution. The modular design
ensures that you can configure the system to meet your application requirements.
A dedicated team of product specialists will provide technical support and provide
an applications development service.
Key Features
◆ Same specifications as popular HPLC
◆ Excellent reliability and stability
◆ Modular design enables flexible configurations
◆ Automatic data save in the event of accidental power off
◆ Optional UVD, DAD, FLD, RID and ELSD
Specifications
L600 Pump | |
Type | Serial dual plunger |
Flow range | 0.001-10.000 ml/min, 0.001 ml/min increment |
Compressive compensation | User defined |
Seal wash | Manual |
Max pressure | 40 Mpa/5800 psi |
Pressure ripple | ≤1 % (1 ml/min, degassed methol) |
Flow precision | ≤0.3 % RSD |
Flow accuracy | 1 % |
Number of solvents and setting range | Isocratic, 0-100 %, 0.1 increments |
Composition accuracy | ≤2 % |
Power requirements | 95-240 V, 50/60 Hz, 150VA |
Dimension | 15.5 x 21.6 x 6.6 in |
Weight | 32 lb |
Sound pressure level | <70dB |
L600 UV Detector | |
Lamp source | Deuterium lamp, Tungsten lamp |
Wavelength range | 190-800 nm |
Bandwidth | 6 nm |
Wavelength accuracy | ±1 nm |
Wavelength precision | ≤0.3 nm |
Linear range | >104 |
Noise | ±0.75x10-5 AU (dry cell, 254 nm, response time 1s) |
Drift | 1x10-4 AU/h (dry cell, 254 nm, responses time 1s) |
Detection limit | ≤5x10-9 g/ml (naphthalene/methanol) |
Flow cell volume | 10 mm, 10 μl |
Pressure limit | 10 Mpa/1450 psi |
Responses time | 0.1-2 s |
Operating temperature range | 10-40 ℃ |
Power requirements | 95-240 V, 50/60 Hz, 150VA |
Dimension | 15.5 x 21.6 x 6.6 in |
Weight | 26.5 lb |
Sound pressure level | <70dB |
L600 Auto Sampler | |
Loop volume (100 μL) | 1-5000 μL programmable (10 mL loop optional) |
Syringe volume | 500 μL (2500 μL optional) |
Sample capacity | 2x48 vial tray for 1.5 mL vial (optional 12 position 10 mL vial tray, 96 well plate formats, 384 well plate formats) |
Switching time of injection valve | <100 ms |
Piercing precision needle | ≤0.6 mm |
Injection cycle time | 17 s (60 s while needle washing) |
Injection modes | Full loop, partial loopfill and μL pickup mode |
Reproducibility | Full loop < 0.3 % Partial loopfill < 0.5 % Μl pickup < 1 % |
Carry over | <0.05 % |
Cooling (optional) | 4 ℃ to ambient-3 ℃ |
Power requirements | 95-240 V, 50/60 Hz, 150VA |
Dimension | 11.8 x 20 x 14 in, 11.8 x 22.6 x 14 in with cooling |
Weight | 42 lb, 46 lb with cooling |
Sound pressure level | <70dB |